The TA330 Breather Valve is tamper-proof and requires no field maintenance.
Corrosion-resistant materials are used throughout. The valve seal is made of
silicone rubber. The spherical valve seat is Teflon coated
for easy "break-away" action even after prolonged storage. Gasket,
washer and hex nut for mounting are provided with each valve. A
weldable nut is available for use as a threaded boss, or the
valve may be used with our 658800 Mounting Flange. RFI/EMI shielding is also available. For additional enclosure protection, AGM can develop a custom desiccant cartridge that mates with the valve.
The TA330 Breather Valve's unique cover and dust baffle provides superior protection from sand and dust intrusion. Additionally, the cover makes this valve well suited for high-pressure hose down applications. When compared to a screened valve such as AGM's TA238 Breather Valve as well as competitors' valves, the TA330 Breather Valve allows virtually no water to pass when subjected to a high-pressure water stream. The TA330 Breather Valve has been tested to the NEMA 250 5.7 high-pressure hose down test; contact AGM's Engineering department for more information.
The TA330 valve is offered in two types: “Cracking” and “Reseal”. Cracking valves are rated by cracking pressure (the pressure at which the valve has opened enough to flow 1 cubic centimeter per minute) and the flow rate at 1.5 psi above the cracking pressure. Reseal valves are rated by reseal pressure (the pressure by which the valve is guaranteed to close after it has cracked open) and the flow rate at 1.5 psi above the reseal pressure.
Note that whether you are specifying a reseal valve or a cracking valve, the flow rate at 1.5 psi above the reseal pressure is usually the most important parameter when selecting a valve: per SAE Specification AS27166, you should select a valve with a flow rate of at least 12% of the container volume per minute at a pressure less than the container’s pressure rating. For instance, when choosing a valve for a container with a volume of 10 cubic feet that can withstand a pressure of 2 psi, the recommended valve would flow 1.2 standard cubic feet per minute (SCFM) at 2 psid or less pressure differential. While at first glance it may appear that a valve with a crack point of 2 psi would be appropriate for this application, remember that the flow rate at crack is very low (1 cc/min) and therefore would very likely not provide adequate pressure relief. Refer to Theory and Characteristics for more information on selecting a breather valve.
Flow rate versus pressure curves are available for some valves. Contact AGM’s Engineering Department if you require this information.
Materials and Finish: Housing, nut and washer are aluminum
with anodized finish. Gasket
material is silicone per A-A-59588, Class II, Grade 60. Torque value
for installation: 30 in. - lbs. (3.4 N•m) Weight:
.10 lbs. (45 grams)
Mounting Requirements: Gasket, washer and hex nut for mounting are provided with each valve. A weldable nut is available for use as a threaded boss, or the valve may be used with our 658800 Mounting Flange.
Mounting hole diameter: 1.05 ± 0.015 (27 ± 0.38 mm)
Installation torque: 30-40 in. - lbs. (3.4-4.5 N•m)
Maximum wall thickness: 0.57 (14 mm)
Add extra washer for wall thickness less than 0.063 (2 mm). (AGM P/N 300013-16, order separately.)
For threaded boss installation: 3/4-14 NPSM.
Contact AGM's Engineering department for information on NEMA and IP ratings.
RESEAL VALVES |
PRESSURE SIDE (FLOW OUT) |
VACUUM SIDE (FLOW IN) |
|
|
|
Dash No. |
Reseal Pressure * |
Flow Rate * |
-025 |
0.25 psid |
3.0 scfm @ 1.75 psid |
-025 |
0.25 psid |
4.0 scfm @ 1.75 psid |
-05 |
0.5 psid |
3.0 scfm @ 2.0 psid |
-05 |
0.5 psid |
4.0 scfm @ 2.0 psid |
-10 |
1.0 psid |
2.5 scfm @ 2.5 psid |
-10 |
1.0 psid |
3.5 scfm @ 2.5 psid |
-15 |
1.5 psid |
2.0 scfm @ 3.0 psid |
-15 |
1.5 psid |
3.0 scfm @ 3.0 psid |
-20 |
2.0 psid |
2.0 scfm @ 3.5 psid |
-20 |
`2.0 psid |
3.0 scfm @ 3.5 psid |
-25 |
2.5 psid |
1.5 scfm @ 4.0 psid |
-25 |
2.5 psid |
2.5 scfm @ 4.0 psid |
-30 |
3.0 psid |
1.5 scfm @ 4.5 psid |
-30 |
3.0 psid |
2.5 scfm @ 4.5 psid |
| *To convert psid to millibars, multiply by 69. To convert scfm to liters/sec, multiply by 0.472. |
| Dash numbers for the Pressure and Vacuum sides may be used in any combination (i.e. TA330-05-15). AGM can also supply TA330 Valves with other settings than those shown above. Please contact AGM for availability. Before making drawings of these valves, contact AGM for part numbers to be used. |
CRACKING VALVES |
PRESSURE SIDE (FLOW OUT) |
VACUUM SIDE (FLOW IN) |
|
|
|
Dash No. |
Cracking Pressure * |
Flow Rate * |
-025C |
0.25 ± 0.15 psid |
4.0 scfm @ 1.75 psid |
-025C |
0.25 ± 0.15 psid |
4.0 scfm @ 1.75 psid |
-05C |
0.5 ± 0.2 psid |
3.0 scfm @ 2.0 psid |
-05C |
0.5 ± 0.2 psid |
4.0 scfm @ 2.0 psid |
-10C |
1.0 ± 0.25 psid |
3.0 scfm @ 2.0 psid ** |
-10C |
1.0 ± 0.25 psid |
4.0 scfm @ 2.0 psid ** |
-15C |
1.5 ± 0.25 psid |
3.0 scfm @ 3.0 psid |
-15C |
1.5 ± 0.25 psid |
3.0 scfm†@ 3.0 psid |
-20C |
2.0 ± 0.25 psid |
2.0 scfm @ 3.5 psid |
-20C |
2.0 ± 0.25 psid |
3.0 scfm @ 3.5 psid |
-25C |
2.5 ± 0.3 psid |
2.0 scfm @ 4.0 psid |
-25C |
2.5 ± 0.3 psid |
2.0 scfm @ 4.0 psid |
-30C |
3.0 ± 0.3 psid |
1.5 scfm @ 4.5 psid |
-30C |
3.0 ± 0.3 psid |
1.5 scfm @ 4.5 psid |
| *To convert psid to millibars, multiply by 69. To convert scfm to liters/sec, multiply by 0.472. |
| **Valves with -10C settings are rated for flow at 1.0 psi above the crack pressure, or 2.0 psid, instead of the usual 1.5 psi above crack pressure. |
| Dash numbers for the Pressure and Vacuum sides may be used in any combination (i.e. TA330-05C-15C). AGM can also supply TA330 Valves with other settings than those shown above. Please contact AGM for availability. Before making drawings of these valves, contact AGM for part numbers to be used. |
|