The
658800 Mounting Flange provides ease of use and design flexibility. It
allows removal of Desiccators, Breather Valves and Humidity Indicators with 3/4 - 14 straight pipe external thread without opening the container.
It also eliminates the need for a threaded boss to be provided
in the container. The
flange is installed by making a 1.265" diameter hole with the provided
nut.
The flange and nut have a corrosion-resisting clear anodize finish. A neoprene
synthetic rubber environmental gasket is included. Other finishes, gasket
materials and RFI/EMI Shielding are available upon request to meet specific
needs.
Mounting Requirements: Each flange comes complete with nut, washer, and gasket.
Mounting hole diameter: 1.265 ± 0.015 (32 ± 0.25 mm)
Installation torque: 70-80 in. - lbs. (8.0-9.0 N•m)
Maximum wall thickness: 0.18 (4.5 mm)
Add extra washer for wall thickness less than 0.054 (1.4 mm). (AGM P/N 440009-16, order separately.)
|